Is NFPA 70B Now a Mandatory Standard? What You Need to Know
A New Era in Electrical Maintenance Standards
Until recently, NFPA 70B was often seen as a “best practice” reference—something to follow, but not necessarily required. That changed with the 2023 edition. The revised document transitioned from a recommended guideline to a Standard for Electrical Equipment Maintenance, prompting a shift in how facilities approach compliance and operational risk. Is NFPA 70b mandatory
While the National Fire Protection Association (NFPA) itself doesn’t enforce laws, the shift in language—from "recommended" to "shall"—positions NFPA 70B to be adopted into regulatory frameworks and safety codes by authorities having jurisdiction (AHJs).
What Changed in the 2023 Edition?
The most impactful change in the updated NFPA 70B is its formal status. No longer a Recommended Practice, it is now published as a standard. That means:
Prescriptive Requirements: The use of “shall” throughout the document reflects enforceable requirements, not just suggestions.
Risk-Based Approach: The standard now mandates condition-based maintenance, a strategic shift from periodic-only schedules.
Defined Maintenance Programs: Facilities must develop and document a formal electrical maintenance program that meets specific criteria.
These changes place new responsibilities on facility owners, maintenance teams, and electrical service providers.
Is It Legally Required?
The short answer: It depends on where you are and how local codes are structured.
NFPA standards—including NFPA 70B—are not inherently law. However, once a standard is adopted by a state, city, insurance provider, or federal agency, it becomes enforceable in those jurisdictions. For example:
OSHA may reference NFPA 70B as an industry standard under the General Duty Clause.
State fire codes or building authorities may adopt NFPA 70B in part or full.
Insurance companies may require compliance with NFPA 70B to reduce liability and validate risk assessments.
If any of these entities require adherence, then the standard effectively becomes mandatory.
Role of Authorities Having Jurisdiction (AHJ)
An AHJ is any entity or individual responsible for enforcing codes, such as:
Local building or electrical inspectors
Fire marshals
OSHA compliance officers
Insurance auditors
They determine whether NFPA 70B applies in your context. If it’s cited in permits, inspection requirements, or insurance risk documentation, noncompliance could result in fines, citations, or policy exclusions.
Even without a legal mandate, many AHJs treat NFPA 70B as a benchmark for due diligence and operational safety.
How the Standard Connects to Other Codes
NFPA 70B is closely aligned with:
NFPA 70 (National Electrical Code) – which outlines safe electrical installation practices
NFPA 70E (Electrical Safety in the Workplace) – which focuses on protecting workers from arc flash and electrical hazards
The trio forms a comprehensive safety ecosystem. NFPA 70B addresses the maintenance component, helping ensure equipment functions properly and stays within safe operating parameters. Poor maintenance can lead to failures that violate NEC installation rules or increase risks covered by NFPA 70E.
In short, failure to follow NFPA 70B can result in broader noncompliance across interconnected standards.
Why Compliance Is Becoming More Commonplace
Many industries are proactively adopting NFPA 70B as part of their standard operating procedures—even if it’s not legally required. Reasons include:
Insurance Incentives – Insurers may offer lower premiums or require proof of preventive maintenance programs.
Corporate Risk Management – Internal policies may mandate NFPA-based programs to minimize downtime or legal exposure.
Contractor Qualifications – Vendors or partners may require NFPA 70B alignment to bid on projects.
Increased Asset Reliability – Structured maintenance improves uptime, performance, and lifecycle cost of electrical assets.
This growing normalization makes NFPA 70B essential reading for operations managers, engineers, and compliance officers.
What NFPA 70B Actually Requires from You
If your organization chooses—or is required—to follow the standard, here’s a breakdown of what you’ll need:
Formal Electrical Maintenance Program (EMP): A written document outlining responsibilities, schedules, equipment inventories, and procedures.
Asset Condition Evaluation: Regular inspections and testing using visual checks, infrared thermography, and electrical diagnostics.
Interval-Based Maintenance: Defined task frequencies based on equipment condition and criticality.
Personnel Qualification: Maintenance staff must be trained and qualified for the tasks they perform.
Recordkeeping: Documented proof of inspections, tests, repairs, and corrective actions.
This isn’t just about avoiding risk—it’s about ensuring consistent reliability and protecting your people, processes, and property.
NFPA 70B in the Context of Electrical Incidents
Data shows that a significant percentage of electrical failures result from a lack of proper maintenance. Neglected components can lead to:
Arc flash incidents
Electrical fires
Equipment damage
Systemwide outages
NFPA 70B addresses these risks head-on by promoting predictive and preventive maintenance that identifies problems before they escalate. For organizations subject to OSHA inspections, demonstrating a structured EMP aligned with 70B can be a strong defense against citations related to unsafe equipment conditions.
Insurance and Legal Liability Implications
If a facility experiences a major electrical failure or fire and can’t show proof of maintenance practices aligned with current standards, it could face serious repercussions:
Increased liability for injuries or property damage
Insurance claims denial for failing to meet standard care obligations
Legal actions by employees or tenants for preventable hazards
Even if NFPA 70B isn’t codified in your area, it may still be used in court or by insurers as a benchmark for expected behavior. Click here
Who Should Be Paying Attention?
Facilities of all sizes and industries—from manufacturing plants and hospitals to data centers and schools—should evaluate their alignment with NFPA 70B. In particular:
Facility managers need to understand what’s required to implement a compliant EMP.
Maintenance supervisors must ensure their teams are trained and equipped to follow standardized procedures.
Executives and legal teams should be aware of potential liabilities and insurance requirements.
Safety professionals need to integrate 70B practices with NFPA 70E programs for a unified approach to electrical hazard control.